Planning calculators for custom homes, additions and major renovations.
Reachability
reachable
checked 2026-11-21 05:34 UTC
Registry status active
Tools pinned 11
0f0334275124
Tools last changed
unchanged since first capture 2026-11-17
Provenance
Registry namespace com.andarehomes
(domain verified by the official registry)
Remote endpoints
https://andarehomes.com/mcp (streamable-http)
Observed changes
| When (UTC) | Event | Detail |
|---|---|---|
| 2026-11-17 05:30 | first capture | 11 tools pinned |
Pinned tool definitions (11)
| Tool | Description |
|---|---|
| toronto-building-permit-checker | Says whether a project in Toronto needs a building permit, usually does not, or depends, with the City source for the answer. Preliminary planning only. Example: /api/tools/toronto-building-permit-checker?project=deck&h=high&att=yes&exit=no |
| garden-suite-zoning-checker | Checks height, separation, floor area, setbacks and lot coverage of a garden suite against Toronto By-law 849-2025. Preliminary planning only. Example:... |
| toronto-permit-review-time-calculator | Gives the last day of the City of Toronto published review time for a complete building permit application, by review stream. Preliminary planning only. Example:... |
| accessible-ramp-and-doorway-calculator | Ramp length for a rise at the Ontario Building Code 1 in 12 gradient, a slope check, or a doorway clear width check, using Section 3.8. Preliminary planning only. Example:... |
| bathroom-exhaust-fan-calculator | Minimum bathroom exhaust fan rating in CFM from room size, ceiling height and fixtures, using the Home Ventilating Institute guidance. Preliminary planning only. Example:... |
| basement-ceiling-height-and-egress-checker | Tests basement ceiling height, height under beams and ducts, and stair headroom against Ontario Building Code Part 9, for a house basement or a secondary suite. Window sizes are tested by the egress window size calculator. Preliminary... |
| egress-window-size-calculator | Tests a bedroom escape window against Ontario Building Code Article 9.9.10.1: open area of at least 0.35 m2, no dimension under 380 mm, sill height and window well clearance. Preliminary planning only. Example:... |
| second-suite-requirements-checklist | A checklist of Ontario Building Code, Planning Act, Fire Code and City of Toronto items to check before adding a secondary suite to a house, each with its section number. Preliminary planning only. Example:... |
| deck-permit-and-guard-checker-toronto | Says whether a deck in Toronto needs a building permit, whether a guard is required, the minimum guard height, opening size and stair handrail rule, from the City of Toronto and Ontario Building Code Part 9. Preliminary planning only.... |
| stair-calculator-ontario | Gives the number of risers allowed for a total rise, the rise and run of each option, and tests headroom and width against Ontario Building Code Part 9 Section 9.8. Preliminary planning only. Example:... |
| renovation-materials-calculator | How much paint, how many drywall sheets or how many boxes of flooring a rectangular room needs, with an adjustable waste allowance. Quantities only. Preliminary planning only. Example:... |